Our company is a respected manufacturer, supplier and exporter of a massive range of Flush Doors. These are ready to use doors which can be easily placed with minimal endeavor. To manufacture these doors, we use chosen and well seasoned imported pine wood timber that are tested by permanent preservatives. The core of the doors is framed with seasoned wood and is made it robust by a layer of cross bands. It makes the Flush Doors resistance against borer, termite and dimensionally stable in natural cyclic changes.
Both side lock rails are provided for sufficient strength to the handles and knobs.
All core, battens and frames are treated with special chemical, which makes the door stable in case of borer and termite attack.
BWP grade PF resin is used during manufacturing which provide long life to doors in any climate.
Applications | : | Pragati flush doors are widely used for residential and commercial complexes, schools, restaurants, hotels, offices, cinema halls, apartments etc. |
S.No | Test | ISI Requirements | Observed Values |
---|---|---|---|
1 | Dimension | Length Width-+ 5 mm, Thickness-+ 1 mm | Within limits |
2 | Squareness | Deviation not more than 1 mm on a length of 500mm | Deviation below 1 mm |
3 | General flateness | Twist, cupping, warping not to exceed 6 mm | |
4 | Local planeness | Depth of deviation at any point to be less than 0.5 mm | Within limits |
5 | Impact indentation test | Depth of deviation not to exceed 0.2 mm | Within limits |
6 | Flexure test | The deflection at the maximum load shall not be more than 1/30 of length and 1/15 of width and the residual deflection should not be more than 1/10 |
Satisfactory |
7 | Edge loading test | Deflection of edge with max To be less than 5mm | Within limits |
8 | Shock resistance test | No visible defect after test | No visible defects |
9 | Buckling test | Initial deflection-<50mm residual deflection-<5mm | Within limits |
10 | Slamming test | No visible damage after test | No visible damage |
11 | Misuse test | No deformation after test | No deformation |
12 | Varying humidity test | No visible warping, twisting or de-lamination | No such defects observed |
13 | End immersion test | No de-lamination at the end | No de-lamination |
14 | Knife test | Minimum pass standard | Excellent |
15 | Glue adhesion test | No de-lamination | No de-lamination |
16 | Screw withdrawal test | Load to withdraw the screw shall not be less than 1000N | 1250 N |